THE ATS LABASSISTANTÔ
The ATS LabassistantÔ automates the sample preparation procedure, eliminating time consuming manual routine work that also can be the cause for errors. Moreover it can also perform unattended sample preparation thus increasing work output reliably. The ATS LabassistantÔ is the combination of an intelligent autodilutor and an intelligent random access autosampler with a robotics program that is factory installed, but that leaves considerable freedom for the analysts own methodologies. Fields of Application: The ATS LabassistantÔ can be used in conjunction with any of the following analysis methods: GC, HPLC, AAS, AE-Flame Photometry (HPFP)Ô, ICP, VIS-UV-NIR, TOC, pH/I.S.E. as well as other similar applications. Whilst the ATS LabassistantÔ combines the functions of the ATS Autodilutor and Autosampler and is thus an intelligent sample preparation station, the autosampler and autodilutor can each be used on their own, should the work of a laboratory require only one of the functions. The ATS autodilutors and autosamplers are designed to simplify complex manual sample preparation procedures in the laboratory. They increase analytical quality and productivity, reduce the cost of analysis and enable laboratories to meet GLP protocols. ATS/20096 Autodilutor The Autodilutor uses a piston type micro-syringe dilutor for high precision volumetric dispensing and operates under a dedicated software control. It uses a standard syringe of 2.5 ml volume, though for specific user applications syringes with other volumes can be supplied. Since with the ATS Autodilutor only micro samples are required for analysis, it is an ideal complement to clinical analysers especially in pediatric and geriatric applications or similar science/industry applications. ATS/20012 or ATS/20012C Autosamplers The ATS autosamplers have easily interchangeable sample trays. Standard trays accept 37 vials (4 ml or 8 ml volume vials). Typical custom designed trays can also be supplied. A special feature is their intelligent routine; all movements are either factory pre-programmed in a sequential mode for clinical routine applications or when used with a PC Data Station, maximum flexibility is offered with the custom-made ATS MiniSoftWin® software package that allows all steps to be user defined in a random access mode as required for science and industry procedures. The ATS/20012 Series Autosampler is the ideal partner to the ATS 200 Series High Performance Flame Photometers (HPFP)Ô: with its intelligent pre-set routine, it automatically presents the samples to be analysed by the analysers. The automatic routine of the ATS/20012C clinical autosampler covers: collection of the sample, collection of the diluent, dispensing both and mixing them in the sample preparation fixed cup. After the analysis two complete automatic rinse and drain cycles give the highest assurance of eliminating cross contamination. The routine can be interrupted so as to analyse a STAT sample (non routine quick analysis) without interfering with the set routine. Intermittent collection of standards or analytical controls can be programmed. Special Features
Technical Specifications ATS/20101 ATS LabassistantÔ intelligent random access sample preparation station for the ATS High Performance Flame Photometers; a microprocessor controlled intelligent autosampler consisting of a software programmable random access sample changer and piston type precision autodilutor with micro sample volume capability down to 5 µl. Accuracy: 0.05% CV within run. Removable sample turntables capable of holding 89 sample vials (4 ml) or 53 positions for 18 ml capacity vials, allows for calibration and QC standards, and with automatic flowthrough rinse station. ATS/20017A Spare Tray for ATS LabassistantÔ with 53 positions, accepts vials of 18 ml capacity ATS/20017B Spare Tray for ATS LabassistantÔ with 89 positions, accepts vials of 4 ml capacity ATS/20017C Spare Tray for ATS LabassistantÔ with 89 positions, accepts vials of 8 ml capacity ATS/20012 Autosampler, a science/industry model with a 37 positions carousel, accepts 4 or 8 ml capacity vials, with dispensing arm, auto rinse, intelligent micro syringe piston dilutor, analysis cup, with auto rinsing capability, emergency sample or spikes control standard position. For 220/240V, 50/60Hz. ATS/20012C Autosampler, clinical model with a 37 positions carousel, accepts 4 ml capacity vials, with dispensing arm, auto rinse, intelligent set-ratio micro-syringe piston dilutor, analysis cup, with auto rinsing capability, emergency sample position as required by "STAT" clinical electrolyte analysis. For 220/240V, 50/60Hz. ATS/20012T Autosampler sample turntable only, as described above but for stand alone sequential presentation of sample (without dilutor). 220/240V, 50Hz only. ATS/20012IT Spare tray with 37 positions for the ATS 20012 science/industry Autosampler. ATS/20012CT Spare tray with 37 positions for the ATS 20012C clinical Autosampler. ATS/20096 Autodilutor, Precision piston type, software programmable. With clinical 1:200 dilution protocol installed, with RS232 for PC communication. ©Advanced
Technical Services GmbH, 1999 All rights reserved.
If
you have questions or comments about this web site please email them
to:
info@ats-technology.com |