ATS 200M ECONOMIC DIGITAL FLAME PHOTOMETER

___________________________________________________________________________

 

The new Swiss Design ATS 200M Modern Digital Flame Photometer, Model ATS/20903 meets the requirements of both, small private laboratories as well as larger laboratories that have few daily analyses to perform. The ATS/20903 model has an automatic electronic flame ignition with an automatic dual safety gas cut-off in case the flame extinguishes, and/or if the electricity is cut off.

Applications include: biochemistry and clinical chemistry, renal dialysis analysis, environmental applications (water, waste waters, etc.) oil, petrochemicals, breweries, wineries, food & beverage (milk, soft drinks, etc.), cement, glass, metallurgy, mining, veterinary laboratories, agriculture (plants, soils, fertilizers, animal tissues, food & feeds, etc.), pharmaceutical quality control and many others.

Technical specifications:

Read-out: digital, bright 3½ digits DPM Display.
Range: 0-199.9 (selectable decimal point).
Measuring Units: ppm, mEq/l, or mmol/L.
Filter Holder: 6 position filter wheel.
Measuring Ranges:

 

Science & Industry Model: Clinical Model:
Na 0 to 200 ppm Na 0 to 200 mmol/L
K 0 to 100 ppm K 0 to 200 mmol/L
Li 1 to 200 ppm Li 0 to 6 mmol/L
Ca 1 to 200 ppm  

 

Specificity:

 

if Na, K, Ca & Li are present in the sample in an equal amount as the Na or K being measured, the interference on the signal reading will be less than 0.5%.
Linearity:  

Science/Industry:

typically better than 1% for 3 ppm Na or K, set to read 100 and measured at mid scale.

Clinical: Na 115-170 mmol/L +/- 2 mmol/L at 140 mmol/L
  K 1- 6 mmol/L +/- 0.2 mmol/L at 4 mmol/L
  Li 0- 3 mmol/L +/- 0.2 mmol/L at 1 mmol/L
  Clinical samples dilution ratio 1:200 or 1:100
Sensitivity: typically, Sodium 2 ppm; Potassium 2 ppm; Lithium 3 ppm,
  Calcium 40 ppm (concentrations that will produce a display of 100 digits or more).
Repeatability: better than 1% CV for 20 consecutive readings (10 ppm Na or K).
Response Time: fast readout in 6 seconds.
Read Time: selectable: continuous, or set at 6 seconds.
Detection Limits: Na, K, Li, 0.09 ppm; Ca 5.00 ppm, Ba 20 ppm.
Solution Consumption: typically 3 ml/minute
Solution up-take range: 2 to 6 ml/minute.
Sample size: typically less than 20 µl for clinical samples (important for pediatric samples).
Fuel supply: normal grade butane, propane, or L.P.G. (household size cylinders), that require no special regulators. Can also be used with natural gas with an appropriate regulator.
Air supply : by air compressor, oil & water free, or from direct line using appropriate air regulator and filters.

How to order:

ATS/20903 Modern Science/Industry Flame Photometer Model ATS 200M for Sodium (Na) and Potassium (K) determination. Complete with start-up kit for Na-K, Instruction Manual and Dust Cover, for 220/240V, 50/60Hz.
ATS/20940 Modern Clinical Flame Photometer for 220/240V, 50/60Hz
ATS/20917 Modern Clinical Flame Photometer same as above but with piston micro syringe auto dilutor (accuracy 0.05% C.V.) For 220/240V, 50/60 Hz.
ATS/20164 Air Compressor, 220/240V, 50 Hz;
ATS/20167 Kit Air Separator

Other voltages/frequencies available.

Optionals: high quality optical filters for elements such as Li, Ca, Ba,..., dilutor, recorder output, printer and many other accessories.

Specifications subject to change without notice.